EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories (overview)
Filters
RFI filters for single−axis controllers E94AZRSxxxx (54 ... 95 A)
8
577
EDS94SPP101 EN 10.2
Mechanical installation
Note!
The filter can be mounted in two ways. From this result different mounting
dimensions.
ƒ Standard mounting: The filter is mounted underneath the standard device.
ƒ Side−by−side mounting: In case of a low depth of the control cabinet, the
filter is rotated by 90° and mounted to the left side of the standard device.
For information on this topic, please see the corresponding mounting instructions.
Electrical installation
L1
1 (BK)
2 (BK)
3 (BK)
PE (GN/YE)
L1L2 L2
L3 L3
+
+
L3
N
PE
L1
L2
F1...F3
X301 X100
X302
E94AZxSxxxx E94ASxExxxxx
K1
SSP94FF610
Mains
Terminal X301 Labelling Description
L1
L2
L3
Connection of the mains phases L1, L2, L3
Connection for the supply−side PE conductor with ring cable lug M8
SSP94FF606
Terminal data
Max. conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
E94AZxS0544 50 0
10 88.5
Hexagon
socket 5
E94AZxS0954 95 000
14 124.0
PE connection data
Æ Starting torque
[mm] [Nm] [lb−in]
E94AZxS0544
M8
12 106 SW 13
E94AZxS0954

Table of Contents