EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories (overview)
General accessories
Shield mounting
8
619
EDS94SPP101 EN 10.2
Permissible cable cross−sections (without cable sheath) of the shield mountings:
EMC clip EMC wire clamp Cable tie
EZAMBHXM007
(fixing clip)
EZAMBHXM006
(C02)
EZAMBHXM003
(C03)
EZAMBHXM004
(C04)
EZAMBHXM005
(C05)
EZAMBKBM
(metallic)
[mm] [mm] [mm] [mm] [mm] [mm]
[in] [in] [in] [in] [in] [in]
2 ... 11.6
0.079 ... 0.456
4 ... 15
0.157 ... 0.59
10 ... 20
0.394 ... 0.787
15 ... 28
0.59 ... 1.1
20 ... 37
0.79 ... 1.46
8 ... 30
0.32 ... 1.18
Tab. 8−5 Clamping range of shield mountings
Select the shield mounting according to the cable characteristics.
Lenze system
cables
EMC clip EMC wire clamp Cable tie
A
[mm
2
]
d
[mm]
EZAMBHXM007
(fixing clip)
EZAMBHXM0
06
(C02)
EZAMBHXM0
03
(C03)
EZAMBHXM0
04
(C04)
EZAMBHXM0
05
(C04)
EZAMBKBM
(metallic)
standard, shielded
1.0 10.3
1.5 11.6
2.5 13.2
4.0 14.5
6.0 16.5
10 19.6
suitable for trailing
1.0 11.2
1.5 12.3
2.5 14.2
4.0 14.8
6.0 17.5
10 20.5
Tab. 8−6 Cable characteristics of Lenze system cables
A Single−core cross−sections of a Lenze system cable (motor)
Standard design or trailing cable
d Cross−section of Lenze system cable/cable shield
Tip!
If a shield mounting cannot be used because of thicker cables, in many cases,
an alternative is possible.
For the EMC shield clamp, the EZAMBHXM006 EMC wire clamp or the metal
EZAMBKBM cable tie, for example, can be used.

Table of Contents

Other manuals for Lenze L-force 9400