9.1.5 ATEX / IECEx Marking
Specific motors together with the pump head of the BPS-2000 pump system are in conformity with the
requirements of the Directive 2014/34/EU and the applicable IECEx standards. The following standards are
tested and confirmed at a certified laboratory.
Electrical apparatus for explosive gas atmospheres. General requirements.
Explosive atmospheres Part 7:
Explosive atmospheres .
Non-electrical equipment for explosive atmospheres Basic method and requirements.
Non-electrical equipment for explosive atmospheres .
The Levitronix
®
Ex motors are marked clearly and in accordance to the ATEX / IECEx directives and standards. The
protection Ex ec means increased safety, non sparking motor.
II 3D Ex h tc IIIC T100°C Dc
Category 3GD (Zone 2 for Gas and Zone 22 for Dust)
Thermal classification of motor is 100 °C (T5) (100 °C = 212 °F) for maximum full-load operating
temperature at a maximum liquid temperature of 90
°C / 194 °F.
9.1.6 Cl1 Div2 Marking
Specific motors together with the pump head of the BPS-2000 pump system are in conformity with the
requirements of the national electrical code NFPA-70 article 500. The following standards are tested and
confirmed at a certified laboratory.
Nonincendive Electrical Equipment For Use in Class 1 and 2, Division 2 and Class 3, Division 1 and 2
Hazardous (Classified) Locations
Nonincendive Electrical Equipment For Use in Class I and II, Division 2 and Class III, Divisions 1 and 2
Hazardous (Classified) Locations
The Levitronix
®
Cl1 Div2 motors are marked clearly and in accordance to the above mentioned standards.
Class I, Div 2 Groups A-D T5
Class II, Div 2 Groups F-G T5
Class I, Div 2 Groups A-D T5
Class II, Div 2 Groups F-G T5
Class I, II (Zone 2 for Gas and Zone 22 for Dust)
Thermal classification of motor is T5 (<100 °C = 212 °F) for maximum full-load operating
temperature at a maximum liquid temperature of 90 °C / 194 °F.