Roller, upper feed removal
1. Remove the rear cover. See “Covers, rear removal” on page 4-5.
2. Remove the top cover. Go to “Covers, top removal” on page 4-5.
3. Remove the screw from the print cable shield, and then remove the shield.
4. Remove the gear from the left end of the upper feed roller, as shown.
5. Remove the two screws (A) from the right upper feed roller bracket. One screw also retains the upper feed
roller ground clip.
6. Pull the upper feed roller from the left bracket and then out of the printer.
7. Be sure to perform the Printhead-to-platen gap adjustment. Go to Printhead-to-platen gap adjustment”
on page 4-2.