2-26 Service Manual
7011-2xx
Cover interlock switch service check
Note: Make sure a print cartridge assembly is installed and the cover closes all the way, engaging the cover
open switch lever.
Dead machine service check
CAUTIONCheck the AC line voltage. The voltage should be within the following limits:
• 100 V ac (volts alternating current) – 127 V ac for the 110 V MFP
• 200 V ac – 240 V ac for the 220 V MFP
FRU Action
Cover interlock switch Check the cover interlock cable to make sure it is not plugged into J9,
and that the cooling fan cable is not plugged ito J11. If they are,
switch plug them into their correct connectors.
Disconnect the cover interlock cable from the controller card at J11.
Verify continuity between cable pin 1 and pin 2 with the door closed
but not open.
Verify continuity between cable pin 1 and pin 3 with the door open but
not closed.
• If either fail continuity, replace the cover interlock switch.
• If both pass continuity, turn the MFP on and verify +5 V dc on pin
2 at J11 on the controller card.
• Verify pins 1 and 3 are ground.
• If voltage or ground is not present, see “Controller card service
check” on page 2-25 for more information.
Verify discontinuity between pins 2 and 3 whether the door is open or
closed.
Replace the cover interlock switch if faulty.
FRU Action
LVPS/HVPS
Unplug the MFP, and check the fuses on the LVPS/HVPS board for
continuity.
• If open, replace the LVPS/HVPS board.
- If fuse opens again, see “LVPS/HVPS service check” on
page 2-28 for more information.
• If not open, unplug the cables at CN102 and CN201 (fuser and
controller card respectively).
Plug LVPS/HVPS board to source, and turn switch on.
Verify 24 V dc on pins 8 and 9 at connector CN201.
Verify line voltage (110 or 220 V ac) across pins 1 and 2 of CN102.
• If either voltage is not correct, replace the LVPS/HVPS board.
• If both voltages are correct, check the controller card. See
“Controller card service check” on page 2-25 for more
information.
Verify grounds.