Command and Response #autoselect
ç GET·/V1/MEDIA/USB/XP/<host>.ConnectedDestinations
æ pr·/<host>.ConnectedDestinations=H1
Parameters
Parameter Parameter description  
<host> USB Host
U1-U4
USB-C and USB-B port number
Example
ç 
æ 
Lock the USB Port
Command and Response #lock
ç SET·<usb_port><locked_state>
æ pw·/V1/MEDIA/USB/XP/<usb_port>.Lock=<locked_state>
Parameters
Parameter Parameter description  
<usb_port> USB Port
U1-U4
H1
USB-C and USB-B port number
USB hub
<locked_state> 
true
false
The port is locked
The port is unlocked
Example
ç 
æ 
Setting the 5V Sending to the USB Peripherals

Command and Response
ç SET·<device_id><device_pwr>
æ <device_id><device_pwr>
Parameters
Parameter Parameter description  
<device_id> USB A-type port
D1-D4
Downstream port number
Auto

power sending.
Off

downstream port
Example
ç 
æ 