USE AND MAINTENANCE MANUAL DLC
NET
Series
Use as a batcher
LOGIC S.r.l. - M0145Db.docx
Mod. L0006A01 of 30/05/2016
Page 65 of 78
Scroll through the button until the menu .
Press to enter.
Press at any time to cancel and return to the previous menu.
The display will show the value currently set (default ).
To change it use the button to choose or
Press to confirm.
At this point the instrument will show the letters and the procedure
is finished.
Use the auto-correction of flight only in case where the line pressure is
constant. In the presence of high error, immediately turn off the auto-
correction.
6.2.4 Configuration of the
expected amount in
flight time ( )
The parameter gives the time in seconds that the instrument waits after
closing the automatic dosing valve before acquiring the data weight for printing.
In other words, when the valve closes (when it was reached a net weight equal to
the setpoint minus the in flight amount), the instrument considers the data stable
after seconds.
For an accurate reporting, choose this parameter in sufficiently large way to
be sure that the acquired data is true and not flow more product on the scale
after the set time.
The instrument accepts the following amount of waiting time in flight values:
2, 5, 15, 30 and 60 s.
To set the parameter :
Enter the menu as described in paragraph 5.3.2.
Scroll through the button until the menu .
Press to enter.
Scroll through the button until the menu
Press to enter.
Press at any time to cancel and return to the previous menu.
The display will show the value currently set (default ).