Chapter 1 Product Description
1-13
1.4 Specifications
Time Slot Interchange
Less than 400 µs delay
One active map, one user stored map
Voice Channel Conversion
A-law to µ-law G.711
CAS Signaling Transparent, (A=0 from E1 becomes A=0 to T1, etc.)
Electrical Power
Field changeable 30W 24Vdc or 30W 48Vdc power supply module
DC : 24Vdc, 3A Max.
48Vdc, 1.6A Max.
AC : 90 to 240 Vac, 50/60 Hz, 2A Max.
Physical
Dimensions 43 x 4.4 x 33 cm, 17” x 1.75” x 13” (WxHxD)
Temperature Range 0 – 50 °C
Humidity 0 – 95% RH (non-condensing)
Mounting Desk-top stackable, 19/23 inch rack mountable
Weight 7.7 lb., (3.5Kg) without plug-in cards
Performance Monitor
Performance Store The last 24 hours performance in 15-minute intervals
Monitor Registers Line, user
Performance Reports
Date & Time, Errored Second, Degraded Minutes, Unavailable Second, Bursty Errored
Second, Severe Errored Second, Controlled Slip Second, and Loss of Frame Count
Alarm History Date & Time, Alarm Type (i.e. Master Clock Loss, RAI, AIS, LOS, BPV, ES, CS)
Threshold Bipolar Violation, Error Second, Unavailable Second, Controllered Slip Second
Network Management
Connector DB9 at front panel
Electrical RS232 interface
Protocol Menu driven VT-100 terminal
Ethernet Port (optional)
Connector RJ45 in rear
Protocol Telnet and Embedded SNMP
Front Panel
Keypads 5 keys, ACO (alarm cut-off), left and right arrows, ESC, and ENTER
LCD 2 lines by 40 characters LCD display
LED 12 - one for each of 9 plug-in slots, power, test, and alarm
Bantam Jacks Network IN, OUT, and Monitor
Rear Panel
CONSOLE
9600, n.8.1
IN OUT MON
K
A
BCDEFHJ
TEST
POWER
ACO
ENTER
ESC
Loop-V
MUXMASTER