Table 3- 4 Performance Parameter List - E1
Performance
Parameter
Description
Definition
2-Frame/Multiframe
Definition
16-Frame/Multiframe
ES Error Second BPV
1, OOF
1, or CS
1. CRC
1, OOF
1, or CS
1.
BES Bursty Error Second 1 < BPV < 2048 1 < CRC < 805
SES Severe Error Second BPV
2048, or OOF
1 CRC
805, or OOF
1
CSS Controlled Slip Second Frame slip
1 Frame slip
1
OOF Out of Frame
1 frame sync loss in 6
consecutive frame bits
1 frame sync loss in 6
consecutive frame bits
LOFC Loss Of Frame Count OOF for 2.5
±
0.5 sec OOF for 2.5
±
0.5 sec
UAS Unavailable Second
10 consecutive SES
10 consecutive SES
DM Degraded Minute BPV
123 CRC
47
Table 3-5 lists the types of reports available, performance parameters provided by each report, and the reset
commands for each report.
Table 3- 5 Performance Report Options
Report Type Category Report
[Menu Command] ES UAS BES SES CSS LOFC BPV ESF
Front Panel Reports USER [Network] Y Y Y Y Y Y Y
1-Hour Terminal USER [Network] Y Y Y Y Y Y

Reports LINE [Network] N/C N/C N/C N/C N/C N/C

Menu Option [1] FAR-END N/C N/C N/C N/C N/C N/C

24-Hour Terminal USER [Network] Y Y Y Y Y Y Y Y
Reports LINE [Network] N/C N/C N/C N/C N/C N/C N/C N/C
Menu Option [2] FAR-END N/C N/C N/C N/C N/C N/C

CRC Error Count USER [Network]

Y X
Terminal Reports LINE [Network]

N/C
Menu Option [E] FAR-END

N/C
Y = Report available and can be cleared by front panel RESET or admin terminal command Y.
X = Report available and can be cleared by front panel RESET or admin terminal command X.
N/C = No clear. Report available, but counts cannot be cleared by the user.
= Report not available.