Chapter 5 Terminal Operation
5-1
5. TERMINAL OPERATIONS
The Loop-V 4200 series provides comprehensive report and enhanced configuration capability through the
console port on the front of the main unit. A VT100 type terminal can be connected to the console port, which
is a standard RS232 interface. Using single-character commands and arrow keys, the Loop-V 4200 can be
configured and monitored. The single-character commands are not case sensitive. On each screen, the
available commands and the configurable fields are highlighted. Alarm messages are also sent to the
console port and are shown on the top of the screen in a blinking mode. Upon power up, the main menu is
shown.
NOTE: On the upper right corner of the screen, a time-of-day display indicates the time the current screen is
shown. Any key, other than ESC, may be pressed to update the screen.
LOOP V4200-9 === Controller Menu === 15:50:49 10/25/2001
Serial Number: 771 Connect_port: SUPV_PORT
Version : HW H/W VER.E SW S3.Q4 05/24/2002
Start Time : 15:35:17 06/25/2002 PWR1: active PWR2: active
[Port Status]
A B C D E F H J K
FT1 FT1 FT1 FT1 FT1 FT1 FT1 2WE&M 4WE&M
[DISPLAY] [SETUP]
C -> Display System Configuration S -> System Setup
Q -> Alarm Queue Summary P -> Password Setup
I -> Information Summary M -> System Alarm Setup
L -> Firmware Download/Upload
T -> Configuration Download/Upload
V -> Store/Retrieve Configuration
[LOG] [MISC]
U -> Choose a Unit A -> Alarm Cut Off
F -> Log Off [SETUP],[MISC] Menu X -> Clear Alarm Queue
O -> Log On [SETUP],[MISC] Menu Y -> Controller Return to Default
Z -> Controller Reset
K -> Load All Ports Default
>>SPACE key to refresh or enter a command ===>
5.1 System Configuration
Press “C” to view the system configuration. There are six choices for baud rate: 38400, 19200, 9600, 4800,
2400, and 1200.
LOOP V4200-9 === System Configuration === 09:51:02 04/12/2001
[System]
IP Interface :ETHERNET_PORT
IP Address :000.000.000.000 Subnet:000.000.000.000 Gateway:000.000.000.000
Trap IP Address:255.255.255.255
Community Name :public
Device Name :LOOP V4200-9
System Location:8F,No. 8,Hsin Ann Rd.
Science-Based Industrial Park
Hsinchu,30077 Taiwan
System Contact :Name: FAE Tel:+886-3-5787696 Fax:+886-3-5787695
E-mail:FAE@loop.com.tw
Baud Rate : 9600 TSI_FUNC: 1:1(Bidirection)
Data Length : 8-Bits
Stop Bit : 1-Bit
Parity : NONE
XON_XOFF : XOFF
<< ESC key to return to previous menu, SPACE key to refresh >>