Appendix A
6-2
Configuration
The multicast function is setup in two places. First the Multicast function must be enabled.
From the main menu, press “S” for System setup.
LOOP V4200-9 === Controller Menu === 10:48:35 09/06/2000
Serial Number: 10001 Connect_port: SUPV_PORT
Version : HW H/W VER.E SW S3.Q4 05/24/2002
Start Time : 15:35:17 06/25/2002 PWR1: active PWR2: active
[Port Status]
A B C D E F H J K
FE1 FE1 FE1 FE1 FE1 o o o o
[DISPLAY] [SETUP]
C -> Display System Configuration S -> System Setup
Q -> Alarm Queue Summary P -> Password Setup
I -> Information Summary M -> System Alarm Setup
L -> Download/Upload Firmware
T -> Download/Upload Configuration
R -> Store/Retrieve Configuration
[LOG] [MISC]
U -> Choose a Unit A -> Alarm Cut Off
F -> Log Off [SETUP],[MISC] Menu X -> Clear Alarm Queue
O -> Log On [SETUP],[MISC] Menu Y -> Controller Return to Default
Z -> Controller Reset
K -> Load All Ports Default
>>SPACE key to refresh or enter a command ===>
Then, move the cursor to the right to “System” and press ENTER.
LOOP V4200-9 === System Setup === 09:25:55 09/06/2000
>> Select System_setup Type ? MAP PORT_BACKUP
*SYSTEM
CLOCK
To set the multicast feature, move the cursor down and to the right to select the “TSI_FUNC” setting.
LOOP V4200-9 === System Setup (SYSTEM) === 09:51:02 04/12/2001
[System]
Time/Date :14:28:37 07/05/2001
IP Interface :ETHERNET_PORT
IP Address :000.000.000.000 Subnet:000.000.000.000 Gateway:000.000.000.000
Trap IP Address:255.255.255.255
Community Name :public
Device Name :LOOP V4200-9
System Location:8F,No. 8,Hsin Ann Rd.
Science-Based Industrial Park
Hsinchu,30077 Taiwan
System Contact :Name: FAE Tel:+886-3-5787696 Fax:+886-3-5787695
E-mail:FAE@loop.com.tw
Baud Rate : 9600 TSI_FUNC:
1:N(Multicast)
Data Length : 8-Bits
Stop Bit : 1-Bit
Parity : NONE
XON_XOFF : XOFF
<< ESC key to return to previous menu >>
Use TAB to change the value to 1:N(Multicast).
Press ESC and save the configuration.