Chapter 7. Function List
7-10
Display Name
Min/Max
range
Description
Factory
defaults
Adj.
during
run
P54
Gain for Motor
rpm display
1 ~ 1000
[%]
It can monitoring on the rpm display
code of drive group as converting
gear ratio of load system.
100 O
P55
Filter time
constant for AI
input
0 ~ 9999
Adjusts the responsiveness of
analogue input.
10 O
P56
Min input for
AI(vol/cur)
0 ~ 100
[%]
Sets the min value of analogue input
as the percentage of the whole input.
0 O
P57
Frequency
corresponding
min input for AI
0 ~ 200
[Hz]
Frequency in case analogue input is
the min value.
0.00 O
P58 AI max input
0 ~ 100
[%]
Sets the max value of analogue input
as the percentage of the whole input.
100 O
P59
Frequency
corresponding
to AI max input
0 ~ 200
[Hz]
Frequency in case analogue input is
the max. value.
60.00 O
P60
Filter time
constant for
Volume input
0 ~ 9999
Adjusts the responsiveness of volume
input operation.
10 O
P61
Min value for
volume input
0 ~ 100
[%]
Sets the min rpm of volume input as
the percentage of the whole input.
0 O
P62
Frequency
corresponding
to volume
input
0 ~ 200
[Hz]
Frequency at minimum current of
volume input.
0.00 O
P63
Max. value of
volume input
0 ~ 100
[%]
Sets the max volume input as the
percentage of the whole input.
100 O
P64
Frequency
corresponding
to volume
input
0 ~ 200
[Hz]
Frequency at maximum volume input. 60.00 O
P65
Criteria for
Analog Input
Signal loss
0 ~ 2
0: Disabled
1: activated below half of set value.
2: activated below set value.
0 O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LS Industrial Systems SV-iE5 Series and is the answer not in the manual?

LS Industrial Systems SV-iE5 Series Specifications

General IconGeneral
BrandLS Industrial Systems
ModelSV-iE5 Series
CategoryInverter
LanguageEnglish

Related product manuals