Table of Functions
450
Cod
e
Comm.
Address
Name
LCD
Display
Parameter Setting
Initial
Value
Property*
Ref.
4
M+G*2*(A
-50)
5
M*(G*2*(A
-50))
6
M/(G*2*(A
-50))
7
M+M*G*2*
(A-50)
8
(M-A)^2
9
M^2+A^2
10
MAX(M,A)
11
MIN(M,A)
12
(M + A)/2
13
Root(M+A
)
14
0h180E
PID
reference
auxiliary gain
PID Ref1
Aux G
-200.0200.0
(%)
0.0
O
p.160
15
0h180F
PID
reference 2
auxiliary
source
selection
PID Ref 2
Src
0
Keypad
0:
KeyPa
d
Δ
p.160
1
V1
3
V2
4
I2
5
Int 485
6
Fieldbus
8
Pulse
9
E-PID
Output
10
47
V3
11
I3
47
‗10(V3)~11(I3) of PID-15 are available when Extension IO option is equipped. Refer to