9-44
9.6 Output terminal select at loder communication error
Group Display Parameter Name Setting Range Default Unit
I/O group
I57
[Output terminal select
when communication
error with keypad]
-
0 ~ 3 0
Select relay output or open collector output when keypad-inverter communication fails.
Keypad and inverter CPU communication is made by serial
communication, delivering information. When communication error occurs
for a certain time, will be displayed and error signal can be
output to MO or relays.
MFI output relay MFI output terminal
Bit 1 Bit 0
0 - -
1 -
3
2
3
-
3
3 3
0: Not used
1: Signal output to MO
2: Signal output to 3A, 3B contacts
3: Signal output to MO, 3A, 3B