Appendix 4 Instruction List
App. 4-40
(5) Exclusive position control instruction (continued)
Classification
Designations
Symbol
Description
Support
XGK
XGB
Error Reset
CLR
CLR naxsl
Resets Error originated from Positioning
Modules ax axis installed on sl slot
Error
History
Reset
ECLR
ECLR axsl
Deletes Error History originated from
Positioning Modules ax axis installed on
sl slot
X
Point
Operation
PST
PST naxsl
Performs Point Operation of Positioning
Modules ax axis installed on sl slot
X
Basic Parameter
Teaching
TBP
TBP n2n1axsl
Changes n2 to n1 among basic
parameters of Positioning Modules ax
axis installed on sl slot
X
Extended
Parameter
Teaching
TEP
TEP n2n1axsl
Changes n2 to n1 among extended
parameters of Positioning Modules ax
axis installed on sl slot
X
Return to Origin
Point Parameter
Teaching
THP
THP n2n1axsl
Changes n2 to n1 among returned
parameters to origin point of Positioning
Modules ax axis installed on sl slot
X
Manual
Operation
Parameter
Teaching
TMP
TMP n2n1axsl
Changes n2 to n1 among manual
operation parameters of Positioning
Modules ax axis installed on sl slot
X
Input Signal
Parameter
Teaching
TSP
TSP naxsl
Changes input signal parameter of
Positioning Modules ax axis installed on
sl slot to the value set in n1
X
Common
Parameter
Teaching
TCP
TCP n2n1axsl
Changes n2 to n1 among common
parameters of Positioning Module
installed on sl slot
X
Parameter
Save
WRT
WRT naxsl
Instructions Positioning Modules ax axis
installed on sl slot to save present
parameter of n axis in flash ROM.
Present State
Read
SRD
SRD Daxsl
Reads and saves present state of
Positioning Modules ax axis installed on
sl slot in D area of CPU
X
Point Operation
Step Write
PWR
PWR n1Saxsl
Writes value of S area of CPU on point
operation step area of Positioning
Modules ax axis installed on sl slot in
X
Plural Teaching
Data
Write
TWR
TWR n1Saxsl
Writes n value of S area of CPU on plural
teaching dada area of Positioning
Modules ax axis installed on sl slot in
X