ND30-09D 41 User's manual
Response:
Device
address Function
Number
of bytes
Value from the register
0FA0 (4000)
Value from the
register
0FA1 (4001)
CRC
checksum
B1 B0 B1 B0
01 03 04 00 0A 00 64 E4 6F
Example 2. Readout of two 32-bit float registers as a combination of two
16-bit registers, starting with the register address 1B58h (7000) - register
values 10, 100.
Request:
Device
address Function
Register address Number of registers CRC
checksum
B1 B0 B1 B0
01 03 1B 58 00 04 C3 3E
Response:
Device
address Function
Number
of bytes
Value
from the
register
1B58
(7000)
Value
from the
register
1B59
(7001)
Value
from the
register
1B5A
(7002)
Value
from the
register
1B5B
(7003)
CRC
checks
um
B3 B2 B1 B0 B3 B2 B1 B0
01 03 08 41 20 00 00 42 C8 00 00 E4 6F
Example 3. Readout of two 32-bit float registers as a combination of two
16-bit registers, starting with the register address 1770h (6000) - register
values 10, 100.
Request:
Device
address Function
Register address Number of registers CRC
checksum
B1 B0 B1 B0
01 03 17 70 00 04 4066