42
Control unit MGCplus
Description of menus and parameters
Operational view > Main menu > Settings > Operating mode
Parameter Description
Emergency options Set the control unit behaviour during an emergency.
If an input is set with the "Emergency open" function or if an input is no
longer set with the "| Emergency open" function, the control unit switches
to emergency mode.
As soon as the input is no longer set with the "Emergency open" function or
if the input is again set with the "| Emergency open" function, the behaviour
of the control unit depends on the setting of the "Emergency options" pa-
rameter.
Options
None: A reset is required for the control unit to switch to normal mode.
ä Page 69, chapter 7.4.
Auto recovery: The control unit automatically switches to normal mode.
Factory setting
Auto recovery
Table 18: Operating mode
6.2.2 Validations
Operational view > Main menu > Settings > Validations
Parameter Description
Hold-open Time –
Change
Set the hold-open time.
The hold-open time is started by an opening pulse by a control device, such
as a card reader. Within the set hold-open time, one passage must be com-
menced. If the hold-open time reaches "0 s" and no person has entered the
pedestrian gate, the validation is lost.
Depending on the parameterisation, it is possible that the passage remains
open because further validations are pending.
With the setting "0 s", the person must already be in the pedestrian gate and
be detected by the light barriers (PE beams), or the validation is lost immedi-
ately.
Once a person has been validated, this validation is maintained until the per-
son leaves the pedestrian gate in any direction.
Setting range
0 to 3600 s (1 hour)
Factory setting
15 s
Hold-open Time –
Set to:
Shows the set hold-open time.
Hold-open Time –
Remaining time
Shows the remaining hold-open time.