Control unit MGCplus
Description of menus and parameters
Operational view > Main menu > Settings > Safety > General
Parameter Description
Impact response
Close
Select the response for obstacle detection during the closing of the wings.
IMPORTANT! The response for unauthorised access attempts is parameter-
ised via the "Impact response Close" parameters of the "Intrusion", "Wrong
direction" and "Tailgating" menus. ä Page 48, chapter 6.2.4.3 up to
ä Page 50, chapter 6.2.4.5.
Options
None: The control unit attempts to continue the closing process of the
wings.
Lock
Open again
Close again
Disable power
Factory setting
Open again
Impact delay Close Set the duration of the response for obstacle detection during the closing.
ä Page 46, "Impact response Close".
Options
3 s, 5 s, 7 s, 10 s or 15 s
Factory setting
5 s
Table 21: General