43 - REVERSING BUZZER ALARM
44 - ROOF SUNSHADE
45 - LOCKABLE CAP
46 - ENGINE BLOCK HEATER
Enables the engine block to be kept warm during prolonged periods of stoppage and
thus improves engine starting.
SUPPLY CHARACTERISTICS OF PREHEATING SYSTEM:
• Rated power supply voltage range:220-240 V;50-60 Hz.
• Current consumed:4.5 A.
• Class1 equipment.
• Equipment can only be connected to TT or TN supply diagrams.
• Installation category2.
ENVIRONMENTAL CONDITIONS FOR USE:
• Maximum ambient temperature for using preheat: +25°C.
• Pollution level2.
CONDITIONS FOR CONNECTION AND USE OF PREHEATING:
- The preheat system should not be used for an external ambient temperature higher than +25°C.
- It is essential that the power supply to the preheating system:
• Is effected with a cable that conforms to the installation standards in force and contains a protective earth conductor.
• Contains an appropriate sectioning system.
Incorporates an appropriate safety system against short circuits (fuses or circuit breaker) and a differential circuit
breaker with30 mA sensitivity.
- Only connect to and disconnect from the power supply while the unit is switched off and the engine is stopped.
2-46