EXHAUST DECONTAMINATION SYSTEM WARNING INDICATOR LAMP
The indicator lamp comes on if the system efficiency is defective. Contact your dealer.
SOOT LEVEL
If the indicator lamp comes on while the lift truck is operating, perform a “STATIONARY LIFT TRUCK EXHAUST REGENERATION
(
e3-MAINTENANCE; OCCASIONAL MAINTENANCE)
.
The indicator lamp also comes on when the count (700h => 0h) before next regeneration has elapsed.
Flashing indicator lamp .
-Perform “STATIONARY LIFT TRUCK EXHAUST REGENERATION.
Fixed
indicator lamp + long audible signal.
-Perform “STATIONARY LIFT TRUCK EXHAUST REGENERATION.
Fixed
indicator lamp + + short audible signal.
-Reduced lift truck efficiency, perform “STATIONARY LIFT TRUCK EXHAUST REGENERATION.
Fixed
indicator lamp +
STOP
+ short audible signal.
Reduced lift truck efficiency, shut down the lift truck and contact your dealer.