Grove Published 11-10-2014, Control # 524-00 9-3
RT880E SERVICE MANUAL LUBRICATION
9
Arctic Lubricants and Conditions
Temperatures Below -9°C (15°F)
Regions with ambient temperatures below -9°C (15°F) are
considered arctic. In general, petroleum based fluids
developed especially for low temperature service may be
used with satisfactory results in these temperatures.
However, certain fluids, such as halogenated hydrocarbons,
nitro hydrocarbons, and phosphate ester hydraulic fluids,
may not be compatible with hydraulic system seals and wear
bands. Therefore, always check with an authorized
Manitowoc distributor or Manitowoc Crane Care if in doubt of
the suitability of a specific fluid or lubricant.
When operating in cold weather and regardless of the oil
viscosity of the crane’s lubricants, always follow the cold
weather start-up and operating procedures described in the
Operator Manual to ensure adequate lubrication during
system warm-up and proper operation of all crane functions.
Cold Weather Package and Lubricants
Manitowoc recommends the following cold weather
lubricants for use with ambient temperatures down to -29°C
(-20°F) (Table 9-1) and -40°C (-40°F) (Table 9-2). But, these
cold weather lubricants alone are not sufficient to operate the
crane in extreme low temperatures. Therefore, it is also
recommended that the crane be equipped with the following
accessories:
-29°C (-20°F) Package
Battery heater
Fuel line heater
Engine hood insulation
Fan clutch
Radiator air shutters
Air diverter
Diesel fired cab heater
Cold weather alternator
Fluids suitable to -29°C (-20°F)
- Arctic windshield washer fluid
- Arctic fuel
-40°C (-40°F) Package
Coolant heater (to circulate warm coolant through
heaters and engine)
Transmission heater
Swivel heater
Battery heater
Fuel line heater
Hydraulic reservoir heater
Engine hood insulation
Fan clutch
Radiator air shutters
Air diverter
Diesel fired cab heater
Cold weather alternator
Super-capacitor starting system
Fluids suitable to -40°C (-40°F):
- Arctic windshield washer fluid
- Arctic fuel

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT880E and is the answer not in the manual?

Manitowoc Grove RT880E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT880E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals