Grove Published 11-10-2014, Control # 524-00 9-15
RT880E SERVICE MANUAL LUBRICATION
9
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Drive Train (continued)
23
Coolant Strainer
(Cab Heater)
Figure 9-4 --- ---
Clean strainer screen
after first 100 hours and
every 2000 hours or 12
months thereafter.
Close shutoff valves.
Unscrew hex plug to
clean filter.
24 Air Cleaner Filter Figure 9-4 --- ---
Replace primary filter
element when
Engine Warning Light
blinks when ignition
key is turned on or
fault code 5576 or
3341 is displayed.
Replace secondary
filter every third time
primary filter is
replaced.
Remove panel
behind ladder to
access air filter.
Refer to Service
Manual
25
Fuel/Water
Separator Filter
Figure 9-4 --- ---
Drain water trap
every 10 hours or
daily.
Change filter every
500 hours or 6
months.
Separator filter is
located below the
fuel tank.
26
Driveline - Slip
Joints
Figure 9-4
EP-MPG
Extreme
Pressure
Multipurpose
Grease
6829003477
Until
grease
extrudes
500 hours or 3 months 2 grease fittings
27 Fuel Filter Figure 9-4 --- ---
Change filter every 500
hours or 6 months
Fuel filter is located
on the top right
frame rail.
NOTE: During replacement of the fuel filter, take note of the direction of the arrow. The arrow must point towards the fuel
filter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT880E and is the answer not in the manual?

Manitowoc Grove RT880E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT880E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals