SET-UP AND INSTALLATION 16000 HANGING MAX-ER® OPERATOR MANUAL
4-52
Published 04-17-17, Control # 067-11
If boom is on ground, it will be necessary to boom up
during this step to properly position mast.
13. Retract hanging counterweight lifting cylinder until beam
support is just clear of ground.
14. Store beam support:
a. Remove pins (11, View G) from assembly position.
b. Using hand winch (9, View A), raise beam support
to stored position and install pins (11, View G).