16000 HANGING MAX-ER® OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
3
This section has two purposes:
To familiarize qualified operators with the location and
operation of specific controls used for MAX-ER
operation.
To alert operators to important safety information
The instructions in this section supplement the operating
control instructions in the Crane Operator Manual.
If the crane is equipped with a luffing jib, see Section 3 of
Luffing Jib Operator Manual for identification and operation
of the luffing jib controls and additional operating
precautions.
MAX-ER SET-UP MODE
The hanging MAX-ER set-up mode must be selected in the
RCL working screen to operate the following controls:
Mast hoist (Drum 4)
Remote control on hanging MAX-ER beam assembly
See Selecting Crane Configuration in RCL Operation
Manual for detailed instructions.
When properly configured, the hanging MAX-ER set-up
capacity chart number and icon will appear on the RCL
working screen as shown in Figure 3-3
.
MAX-ER REMOTE CONTROL
Crane Serial Number 16001128 and Newer
The swing and travel alarm will sound continuously when a
function is being operated with any of the following controls:
Carbody Manual Remote Controls — Priority 1
Crane Setup Remote Control — Priority 2
Wheeled MAX-ER Setup Remote Control — Priority 3
Hanging MAX-ER Setup Remote Control — Priority 4
Additionally on cranes meeting 2010 European
Requirements and with crane software version FCN 2.654
and newer:
No two remote controls can be operated at the same
time. Each has an operating priority as indicated above.
If you try to operate two remote controls at the same
time, the remote control with the higher priority will
operate. The other remote control will be disabled
(turned off).
NOTE: Cranes Meeting 2010 European requirements
have an RCL override switch mounted on the rear
of the operator’s cab (see Rated Capacity
Indicator/Limiter Manual).
Turning On Remote Control
To turn on the hanging MAX-ER remote control, proceed as
follows:
1. In function mode screen, enter MAX-ER remote control
data box (Figure 3-4
).
2. Scroll up or down to turn on remote control (Figure 3-5
).
The flashing prompt indicates the remote control is
communicating properly.
RCL Working Screen
Hanging MAX-ER
Set-Up Mode Icon
FIGURE 3-3