Manitowoc Published 04-17-17, Control # 067-11 3-9
16000 HANGING MAX-ER® OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
Diagnostic Screen
Select MAX-ER icon in diagnostic screen level 1 as shown in
Figure 3-9
. Press Enter button to go to level 2.
There are two level 2 MAX-ER diagnostic screens
Figure 3-10
:
• MAX-ER diagnostic screen 1 which does not apply to
the hanging MAX-ER. It applies only to the wheeled
MAX-ER
• MAX-ER diagnostic screen 2
MAX-ER DIAGNOSTIC SCREEN 1
DOES NOT APPLY to Hanging MAX-ER
Applies only to Wheeled MAX-ER
HM-3-9a
FIGURE 3-10
MAX-ER Diagnostic Screen 2
HM3-9b
Item Description Function
1 Telescopic Beam
DO NOT APPLY to Hanging MAX-ER
Applies only to Wheeled MAX-ER
2 Telescopic Beam Hinge Pins
3 Wireless Remote Control
4 Mast Stop Position (not available on
Crane Software Version M002066
or newer)
and Backhitch
Displays mast stop position (%) and backhitch tension.
5 Counterweight Lifting Cylinder Displays counterweight lifting cylinder position (%):
• 100% = Fully Extended
• 0% = Fully Retracted
Also displays extend and retract pressure (psi or bar)
1
2
3
4
5