16000 HANGING MAX-ER® OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
3
MAIN DISPLAY
See Main Display topic in Section 3 of Crane Operator
Manual for detailed instructions on the main display.
The MAX-ER icons always depict a wheeled
counterweight, even when a hanging counterweight is
attached to the crane.
Information Screen
The information screen displays the MAX-ER information
shown in Figure 3-7
and the fault shown in Figure 3-8. Press
scroll button to access the MAX-ER information screens.
There is only one fault that can be activated during hanging
MAX-ER operation:
Fault # 48 – MAX-ER System Fault which is activated by
a faulty sensor:
- Counterweight lifting cylinder pressure sensor out of
range. Corresponding sensor reads 0 psi (bar)
when cylinder is extending, retracting, or holding the
counterweight OR corresponding sensor reads
7,500 psi (517 bar) when counterweight is on
ground (no load on cylinder).
- Counterweight lifting cylinder position sensor out of
range. Reads 100% when cylinder is retracted.
Reads 0% when cylinder is extended.
- Mast stops compressed too much. The fault will
come on and the mast hoist will be inoperable when
the reading is 0.15 ft (0,046 m).
Fault # 27 – Mast Stop Retracted
MAX-ER lift and boom hoist up will be disabled. This fault
cannot be bypassed. This fault will also activate if Node-6
electric cables are not connected properly.
NOTE: Fault #27 will only be available with crane software
version M002066 or newer. The MAX-ER mast
stop position information screen will not be
available. See Mast Stop Limit Switch operation
procedure.
Mast Stop Limit Switch
Software Confirmation
Inspect and test the mast stop limit switch (software version
M002066 and newer) during MAX-ER setup as follows:
1. Inspect the limit switch lever and actuating lever for
freedom of movement.
2. Confirm Fault #27, Mast Stop Retracted, is active on the
crane display when the mast stop limit switch is tripped
at 26
o
.
Mast Tension
U.S. Tons
Counterweight
Lifting Cylinder
Hanging
Counterweight
30 Retract Raise
25 Stop Raising Tray
10 Extend Lower
15 Stop Lowering Tray
Counterweight lifting cylinder will stop extending if straps
get too slack.
Telescopic Beam Length
DOES NOT APPLY to
Hanging MAX-ER
Applies only to Wheeled MAX-ER
FIGURE 3-7
Counterweight Lifting
Cylinder Extension (%)
100% = Fully Extended
0% = Fully Retracted
Mast Stop Position
(feet or meters).
Not available on
Crane Software
Version M002066
or newer.
HM3-6a
HM3-6c
MAX-ER INFORMATION SCREENS
HM3-6b
FIGURE 3-8
HM3-7a
System Fault Icon
Fault_27
Mast Stop Retracted.
Crane Software Version
M002066 or newer.