DKR Drive Controllers Technical data 4-1
DOK-DIAX03-DKR********-PR02-EN-P
4 Technical data
4.1 DKR02
Designation of the drive controllerDesignation Symbol Unit
DKR02.1-W200-...
DKR02.1-F200-...
DKR02.1-W300-...
DKR02.1-F300-...
Rated power voltage U
N1
V
3xAC 400 ... 480, ± 10%
System frequency f
N1
Hz 50 ... 60
Control voltage U
N2
V
AC 230 V, ± 10%
Control voltage frequency f
N2
Hz 50 ... 60
Control voltage power P
N2
VA 200
Continuous current of the drive
(4 kHz/8 kHz)*
I
conteff
A 4 kHz: 120
8 kHz: 95
4 kHz: 141
8 kHz: 110
Peak current of the drive I
maxeff
A 141 212
Continuous power of the drive
(4 kHz/8 kHz)*
(as relates to the driven shaft of motor,
at 3xAC 400 V, -5%)
P
cont
kW 4 kHz: ca. 47
8 kHz: ca. 37
4 kHz: ca. 55
8 kHz: ca. 43
Peak power of the drive (4 kHz/8 kHz)*
(as relates to the driven shaft of motor,
at 3xAC 400 V, -5%)
P
max
kW ca. 55 ca. 93
Continuous regenerated power P
rück
kW ca. 37 ca. 43
Peak regenerated power (max. 10 s) (as
relates to the driven shaft of motor)
P
rückmax
kW ca. 55 ca. 93
Drive controller power voltage U
eff
V 0 ... 380
max. frequency of the power voltage
(4 kHz/8 kHz)*
f
max
Hz 4 kHz: 800
8 kHz: 1600
Total heat dissipation at I
conteff
P
Vges
W 1600 1800
Heat dissipation in air channel or with
coolant at I
conteff
P
Vext
W 1000 1200
Auxiliary brake resistor (Option)
max. braking energy of the brake
resistor
W kWs 240
Continuous power of the brake resistor P
BD
kW 1,5
Peak power of the brake resistor P
BS
kW 90
Cooling method
build-in blower / coolant
Weight
Drive controller m kg ca. 104
Accessories kit M1-RAC 3 m kg 1,7
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01