DKR Drive Controllers Technical data 4-3
DOK-DIAX03-DKR********-PR02-EN-P
Auxiliary brake resistor (Option)
max. braking energy of the brake
resistor
W kWs 150
Continuous power of the brake resistor P
BD
kW 1
Peak power of the brake resistor P
BS
kW 40
Cooling method
build-in blower
Weight
Drive controller m kg approx. 49
Accessories kit M1-RAC 3 m kg 1,7
Ambient conditions
Perm. ambient temp. range with rated
data
T
A1
°C +5 ... +45
Max. perm. ambient temp. with derating
of nominal data to 80%
T
A2
°C +55
Storage and shipping temperature T
L
°C -30 ... +80
Max. installation elevation without
nominal data derating
m/sea lev. 0 ... 1000
Protection category IP 20 per EN60529 / IEC529
*: Tact frequency of the power section
Fig. 4-2: Technical data DKR03
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01