EasyManua.ls Logo

Manufacture Technology GEFXL2-CSW28KX - Device Type; Port List

Default Icon
311 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication date: March, 2012
Revision A1
219
1. Output : Enable the 1 pps clock output
2. Input : Enable the 1 pps clock input
3. Disable : Disable the 1 pps clock in/out-put
External Enable :
This Selection box will allow you to configure the External Clock output.
The following values are possible:
1. True : Enable the external clock output
2. False : Disable the external clock output.
VCXO_Enable :
This Selection box will allow you to configure the External VCXO rate adjustment.
The following values are possible:
1. True : Enable the external VCXO rate adjustment
2. False : Disable the external VCXO rate adjustment
Clock Frequency:
This will allow setting the Clock Frequency. The possible range of values is 1 - 25000000
(1 - 25MHz)
PTP Clock Configuration
Delete:
Check this box and click on 'Save' to delete the clock instance.
Clock Instance:
Indicates the Instance of a particular Clock Instance [0...3]. Click on the Clock Instance
number to edit the Clock details.
Device Type:
Indicates the Type of the Clock Instance.There are five Device Types.
1.Ord-Bound - clock's Device Type is Ordinary-Boundary Clock.
2.P2p Transp - clock's Device Type is Peer to Peer Transperent Clock.
3.E2e Transp - clock's Device Type is End to End Transperent Clock.
4.MastrOnly - clock's Device Type is Master Only.
5.SlaveOnly - clock's Device Type is Slave Only.
Port List:
Set check mark for each port configured for this Clock Instance.
2 Step Flag:
Static member: defined by the system, true if two-step Sync events and Pdelay_Resp
events are used.
Clock Identity:
It shows unique clock identifier.
One Way:
If true, one way measurements are used. This parameter applies only to a slave. In
oneway mode no delay measurements are performed, i.e. this is applicable only if
frequency synchronization is needed. The master always responds to delay requests.
Protocol:
Transport protocol used by the PTP protocol engine. You can scroll to select the protocol

Table of Contents