3-22.2 Status
This chapter allows the user to monitor the PTP configuration status and inspect the current
PTP clock settings.
Web Interface
To monitor the PTP status in the web interface:
1. Click Configuration, PTP then status.
2. Evoke “Auto-refresh to enable the switch to update the PTP status automatically.
3. Click Refresh to update the Status information manually.
.
Figure 3- 22.1: The PTP status
Parameter description:
One_pps_mode:
Shows the current One_pps_mode configured.
1. Output : Enable the 1 pps clock output
2. Input : Enable the 1 pps clock input
3. Disable : Disable the 1 pps clock in/out-put
External Enable:
Shows the current External clock output configuration.
1. True : Enable the external clock output
2. False : Disable the external clock output
VCXO_Enable:
Shows the current VCXO rate adjustment configuration.
1. True : Enable the external VCXO rate adjustment
2. False : Disable the external VCXO rate adjustment
Clock Frequency:
Shows the current clock frequency used by the External Clock.The possible range of
values are 1 - 25000000 (1 - 25MHz).
Clock Instance:
Indicates the Instance of a particular Clock Instance [0..3]. Click on the Clock Instance
number to monitor the Clock details.
Device Type:
Indicates the Type of the Clock Instance.There are five Device Types.
1.Ord-Bound - Clock's Device Type is Ordinary-Boundary Clock.