8.7.3 Intercom call groups
For each button GSW2 PLUS incorporates a group of parameters. There are 2 groups of parameters.
8.7.3.1 xTN1 to xTN5 parameters
Parameters are the call numbers for intercom application.
8.7.3.2 RTNx parameter
Parameter defines the ring time time-out. RTNx timer is started when the call button is pressed. If
the RTNx timer expires before the GSM voice connection is established then GSW2 PLUS device
calls the next number in XTN1-XTN5 call list.
8.7.3.3 DTMF auto dial functionality
This function is used to provide a support for GSW2 PLUS device to be able select extended
numbers via DTMF command.
8.7.3.4 SDNx parameter
Parameter is used to set the DTMF number in auto self select function.
8.7.3.5 SDDx parameter
Parameter is used to set the delay (in seconds) for sending DTMF number in auto self select
function.
8.7.3.6 Time zone
Time zone support. When time limits are sets (TZSx and TZEx) time zone functionality is ON.
When the current time is in the limits of the time zone parameters the button event calls the number
from xTN1 to xTN4, else button event calls xTN5.
8.7.3.6.1 TZSx parameter
Parameter is used to configure the start time for the time zone functionality - 24h time format.
8.7.3.6.2 TZEx parameter
Parameter is used to configure the end time for the time zone functionality - 24h time format.