8.5 SET-UP PARAMETERS
Different parameters are used to support versatile functionality of GSW2 PLUS.
8.5.1 WMOD parameter
Parameter is used to define mode of operation of the inputs (alarm or intercom mode).
If the input number is not stated in the WMOD parameter then this input is in alarm mode, else it is
in intercom mode.
8.5.2 HTN parameter
Hidden telephone number is a parameter used in order to conceal the telephone number of the
GSW2 PLUS device. The default value is set to “1” which means that the number is displayed.
8.5.3 UDC parameter
Parameter is used to synchronise GSW2 PLUS clock to GSM network clock. User must enter here
the number of the GSW2 PLUS SIM card (Telephone number of GSW2 PLUS device).
8.5.4 RAN parameter
Parameter is used to provide support for auto-answer options for GSW2 PLUS device. The number
defines the numbers of rings needed for GSW2 PLUS device to answer the incoming call. The
incoming number must be on the TN list for GSW2 PLUS device to answer.
8.5.5 TST parameter
A test SMS is sent periodically. GSW2 PLUS can send the test message in the interval ranging from
1 hour to 8760 hours.
Example:
To send test SMS TST value is set to 12, the numbers linked to LN5 receive a test
message every 12 hours.