Page 34
8.13.1 LOGN parameter
Parameter is used for defining the number of events printed out on PLOG request.
8.13.2 LOGI parameter
LOGI parameter is used to enable and define GSW2 PLUS log storage.
- LOGI=0 Logging is OFF
- LOGI=1 Logging in internal memory
- LOGI=2 Logging to USB interface
8.13.3 ALC parameter
Parameter is used to control behavior when log on GSW2 PLUS is full. User can select between
auto log clear or manual clear of log.
- ALC = 0 Manual log erase needed when log is full
- ALC = 1 Automatic log erase when log is full
8.13.4 Table of parameters
Number of log events for printing out
Table 24: LOG parameters
Example:
Direct programming on the SIM card
GSW2 PLUS PROGRAMMING TABLE
5 log events will be printed out on PLOG command
Logging in internal memory
Log is auto cleared when full
Table 25: LOG parameters example.
Remote programming by SMS
;LOGN=5;LOGI=0;ALC=1;
8.14 SPECIAL SMS COMMANDS
These commands can only be issued only over SMS message, and are used to control some special
functions of GSW2 PLUS device.
8.14.1 ORC command
Command is used to control outputs directly via SMS message