13
Example:
Direct programming on the SIM card
ZEUS4-VD PROGRAMMING TABLE
OFF – connecting GND on ON/OFF input
Alarm activated by connecting to GND
Alarm activated by disconnecting GND or +12V
Alarm activated by connecting +12V
Alarm activated by connecting to GND + RST SMS
Table 4: IN parameters example
Remote programming by SMS
;ION=0;IN1=0;IN2=1;IN3=2;IN4=4;
11.2.2 ID parameters
ID parameter determines time period of the pulse length to trigger the Input. The pulse time can be
from 0.5 seconds to 9999 seconds. Minimum time is 0.5 seconds when the parameter value is 0.
Table of parameters:
Default ID filter is 0.5 seconds – ON/OFF input
Default ID filter is 0.5 seconds – input 1
Default ID filter is 0.5 seconds – input 2
Default ID filter is 0.5 seconds – input 3
Default ID filter is 0.5 seconds – input 4
Table 5: ID parameters
Example:
Direct programming on the SIM card
ZEUS4-VD PROGRAMMING TABLE
Default ID filter is 0.5 seconds – ON/OFF input
ID filter is 5 seconds for input 1
ID filter is 30 seconds for input 2
ID filter is 2 seconds for input 3
ID filter is 0.5 seconds for input 4
Table 6: ID parameters example
Remote programming by SMS
;DON=0;ID1=5;ID2=30;ID3=2;ID4=0;