16
11.2.5 LN Parameters
These parameters are used to link alarm event from inputs or any other source to the telephone
numbers on TN list.
Table of parameters:
Input & telephone No. linking for 1
st
alarm input (TN1 – TN0)
Input & telephone No. linking for 2
st
alarm input (TN1 – TN0)
Input & telephone No. linking for 3
st
alarm input (TN1 – TN0)
Input & telephone No. linking for 4
st
alarm input (TN1 – TN0)
Power down, telephone No. linking (TN1 – TN0)
Low Battery, telephone No. Linking (TN1 – TN0)
Periodic test SMS, telephone No. linking (TN1 – TN0)
SIM card refill, telephone No. linking (TN1 – TN0)
Tamper switch, telephone No. linking (TN1 – TN0)
Unauthorized call or SMS, telephone No. linking (TN1 – TN0)
Log status, telephone No. linking (TN1 – TN0)
Table 11: LN parameters
Example:
Direct programming on the SIM card
ZEUS4-VD PROGRAMMING TABLE
Refill SIM – SMS is sent to TN1 & TN2
Input1 is called/sent SMS to TN1 & TN3
Input2 is called/sent SMS to TN1, TN2 & TN3
Input3 is called/sent SMS to TN5
Input4 is called/sent SMS to send to TN4 & TN5
Periodic Test SMS is sent to TN1 & TN2
Table 12: LN parameters example
Remote programming by SMS
;LN8=12;LN1=13;LN2=123;LN3=5;LN4=45;LN7=12;