20
AR – parameter defines the maximum number of alarms trigged in IT time
IB – IB parameter defines how long (in seconds) sending of alarm events is blocked when
automatic input block system in enabled.
Table of parameters:
Maximum allowed number of events on 1
st
input
Maximum allowed number of events on 2
nd
input
Maximum allowed number of events on 3
rd
input
Maximum allowed number of events on 4
th
input
System block time on 1
st
input
System block time on 2
nd
input
System block time on 3
rd
input
System block time on 4
th
input
Table 19: IT, AR and IB parameters
Example:
Input 1 will be blocked for 10 minutes if 10 alarm events are triggered within 125 seconds
Input 2 will be blocked for 1 hour if 5 alarm events are triggered within 12 minutes.
Direct programming on the SIM card
ZEUS4-VD PROGRAMMING TABLE
Max number of alarm events on input 1
System block time on input 1
Max number of alarm events on input 2
System block time on input 2
Table 20: IT, AR and IB parameters example
Remote programming by SMS
;IT1=125;AR1=10;IB1=600; IT2=720;AR2=5;IB2=3600;
Arm/disarm events on ZEUS4-VD resets bypass function.