11.2.6 MAIN and BATT parameter
ZEUS4-VD can send an SMS message in case of the main power failure. SMS message is sent to
user. You can also program how long the unit can stay without power before sending this message.
ZEUS4-VD can control battery level and sends 3 SMS messages when following voltage level on
battery is reached: 11.5V, 10.5V and 9V. It sends the “Low Battery” and battery level in volts SMS
message together.
The low battery level can be detected when the unit works without main power supply.
Should the battery power rise again above 11,5V ZEUS4-VD sends an SMS message with the
following text: “Low Battery restored”.
NOTE
Parameter MAIN determinates time out control after which the ZEUS4-VD will send “Main Power
Lost alarm”. Time can be set between 1 and 9999 seconds.
Parameter BATT determinates time out control after which the ZEUS4-VD will send Battery power
level notifications. Time can be set between 1 and 9999 seconds.
Table of parameters:
Name
Comment
MAIN
Main Power Lost filter
BATT
Battery Power Lost filter
Table 13: MAIN, BATT parameters
Example:
Direct programming on the SIM card
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
MAIN
5
Main power must be down 5s to send alarm.
BATT
20
Battery level must be stable for 20s to send alarm.
Table 14: MAIN, BATT parameters example
Remote programming by SMS
;MAIN=5;BATT=20;