11.8 EVENT LOG PARAMETERS
ZEUS4-VD has a small set of parameters to manage log memory.
11.8.1 LOGN parameter
LOGN parameter is used to define the number of log events that will be send out in case of PLOG
command
11.8.2 LOGI parameter
LOGN parameter is used to enable and define ZEUS4-VD log storage.
LOGI=0 Logging is OFF
LOGI=1 Logging in internal memory
LOGI=2 Logging to USB interface
11.8.3 ALC parameter
ALC parameter defines an action in case when the LOG memory is FULL
ALC=0 Automatically delete buffer when memory is FULL
ALC=1 Memory buffer must be deleted manually when it is FULL
Table of parameters:
Name
Comment
LOGI
Log storage
LOGN
Number of log events for print
ALC
Control for memory handling in case memory storage is full
Table 33: LOG parameters
Example:
Direct programming on the SIM card
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
LOGI
1
Use internal ZEUS4-VD storage
LOGN
10
Send 10 events in case of PLOG request
ALC
1
Automatically delete memory buffer when is full
Table 34: LOG parameters example
Remote programming by SMS
;LOGI=1;LOGN=10;ALC=1;