57
Appendices
®
Syntax DATA Function Comment
PAS pp Stores program
00 or 10 to pp,
depending on
pp
See PAW
PAW ppvvvvvx...x Write a volume
& pattern
to memory.
Length of x
depends on pp
pp - program to write to (00
19)
vvvvv - volume (00001
- 20000)
x - 12 ‘1’ & ‘0’
for programs 00–09
24 ‘1’ & ‘0’
for programs 10–19
ex:
PAW0100005110110110110
PCR Reads the
internal pump
count
Returns a seven character
string 0000000 through
2684354
PCW xxxxxxx Sets the internal
pump count
Must be a seven character
string 0000000 through
2684354
PPR Returns the
pump pause
value xxxx
Returns a 4 digit number 10
msec units
PPW xxxx Sets the pump
pause value
4 digit number in 10 msec
units
PS Xxxxx
Possible
values
= 0400–
20000.
Pump: Set
pump speed
Lowest number
represents the
fastest speed;
highest number
represents the
slowest speed.
Pulses per sec/range
Standard (normal) pump
operating speed = PS00492.