4.2 Manual Material Feed Operation
Operators less familiar with automatic feeding controls may want to use the manual mode for the rst several
hours of operation to become familiar with the other controls and operation.
Single Operator Feed Setup
Left hand operators station controls all feed systems.
At left hand operators station:
1. With left hand operator station as the active station,
select single feed mode.
2. Move left hand auger switch (1) to manual position.
3. Move left hand auger direction switch (2) to out ◄
position.
4. Move left hand conveyor switch (3) to manual position.
5. Move right hand auger switch (4) to manual position.
6. Move right hand auger direction switch (5) to out ►
position.
7. Move right hand conveyor switch (6) manual position.
Dual Operator Feed Setup
Right hand operators station controls all feed systems.
At right hand operators station:
1. With right hand operator station as the active station,
select single feed mode.
2. Move left hand auger switch (1) to manual position.
3. Move left hand auger direction switch (2) to out ◄
position.
4. Move left hand conveyor switch (3) manual position.
5. Move right hand auger switch (4) to manual position.
6. Move right hand auger direction switch (5) to out ►
position.
7. Move right hand conveyor switch (6) auto position.