MC100
Mobile programmable gateway
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
32
Example: Read out Input I1
Command: cat /sys/gpio_board/input1/value
Response: e.g. 1# or 0#
Digital Outputs
All outputs have an identical behaviour. The description here is only for one output (x = 1 to
8 MC100 GPIO).
All switching outputs are represented by solid state relays. OxA occupies one pin of the
switch, OxB the second pin. All outputs are galvanically isolated. The maximum switching
current is 300mA. The maximum applied voltage must not exceed 30V.
Function: Switching the digital outputs
Example: Switch on output O1A,O1B
Command: echo 1 > /sys/gpio_board/output/value
Response: #
Voltage inputs 0 – 10V
Positive connection Input 1
Negative connection Input 1
Positive connection Input 2
Negative connection Input 2
The input current at 10V is approx. 2 mA
Note: The applied DC voltage must not exceed 10V.