EasyManua.ls Logo

MC Technologies MC100 - Combine Data for 1 H, 6 H, 1 Day and Send Via FTP;SCP; Support

MC Technologies MC100
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC100
Mobile programmable gateway
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
62
Combine data for 1h, 6h, 1day and send via FTP/SCP
Collect messages for the whole day as interpreted json, but only send messages
from manufacturer SEO to a server at the end of the day in a zip file.
Support
Please execute mcwmbus -- vV and sent the output together with your error
description and any error message to support@mc-technologies.net
It will be helpful if you run the command that produced the error with -vvvvvv to turn
on the maximal debug information.
while true;
do
mcwmbus -F json -f "wmbus_messages/%M.json" &
sleep 86400 # = 60*60*24 = 24 hours
killall mcwmbus
zip SEO.zip wmbus_messages/4caf.json
scp SEO.zip 192.168.1.1:/data/SEO-`date "+%Y-%m-%d"`.zip
rm SEO.zip
done