MC100 SensorBox
Digital Inputs
Digital inputs
Input voltage: 0 to 30V
Switching threshold: approx. 6V
Function: Reading the digital inputs I1 to I8
/sys/sensor_carrier_board/inputs/isoInput0/value
/sys/sensor_carrier_board/inputs/isoInput1/value
/sys/sensor_carrier_board/inputs/isoInput2/value
/sys/sensor_carrier_board/inputs/isoInput3/value
Example: Read out input IN0
Command: cat /sys/sensor_carrier_board/inputs/isoInput0/value
Response: e.g. 1# or 0#
Digital Outputs
All outputs have an identical behaviour.
All switching outputs are represented by solid state relays. All outputs are galvanically
isolated. The maximum switching current is 300mA. The maximum applied voltage must not
exceed 30V.
Function: Switching the digital outputs
/sys/sensor_carrier_board/outputs/output1/value
/sys/sensor_carrier_board/outputs/output2/value
Example: Switch on output ISO OUT1
Command: echo 1 > /sys/sensor_carrier_board/outputs/output1/value
Response: #
Example: Value = 6400 corresponds to 6.4V