Function: Switch ON, OFF (v1.0.8 and older)
Port
Parameter
Read
Write
Path
COM, NO
1,0
x
/sys/sensor_carrier_board/ac/acout/value
Example: Switch ON Relay
Command: echo 1 > /sys/sensor_carrier_board/ac/acout/value
Response: #
AC IN Relais
Function: Switching the digital outputs (v1.0.8 and older)
Example: Read out AC input status
Command: cat /sys/sensor_carrier_board/ac/acin/value
Response: 1,0
Port
Parameter
Read
Write
Path
AC IN
1,0
X
/sys/sensor_carrier_board/ac/acin/value