Pump Motor
Electric motors are not explosion proof. Operation
of these components in an explosive atmosphere
without necessary safety precautions will result in
serious injury or death.
For operation in an explosive atmosphere consult the instructions
in the "Special Operation" section of this manual.
Locate pump motor in a safe environment. Plug the electrical cord
into a proper power source.
Turn on hydraulic pump motor and note pressure at the relief
valve.
Set the system pressure to 900 psi for most pipe sizes and SDR's.
When facing heavy wall pipe, it may necessary to increase the
pressure to 1200 psi. Reduce the pressure to 900 psi when facing
is completed. Prolonged operation at increased pressure can over-
heat the oil
IMPORTANT: Unplug heater when starting pump motor. This will
reduce the load on the power supply.
TX02135-05-09-14
Install Clamping Inserts
Select and install appropriate clamping inserts for the pipe that is
being fused.
Clamping inserts are required for all sizes except 8" DIPS.
TX01310-4-1-97
Butt Fusion Procedure
PH00304-9-24-93
3 - 3