McElroy 28 - Check Heater Temperature; Select the Fusion Position

Default Icon
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Check Heater Temperature
NOTICE: Incorrect heating temperature can result in
questionable fusion joints. Check heater plates
periodically with a pyrometer and make necessary
adjustments.
Refer to the "Maintenance" section of this manual for instructions
how to adjust heater temperature.
Check heater surface temperature.
Refer to the pipe manufacturer's recommendations for proper
heater temperature.
IMPORTANT: The dial thermometer on the heater indicates internal
temperature which varies from the actual surface temperature.
The dial thermometer can be used as reference once the surface
temperature has been verified.
TX02001-11-1-02
Select the Fusion Position
Move selector valve handle down to the fusing position.
TX00376-9-15-94
Butt Fusion Procedure
3 - 7
WR00077-4-16-93
CD00138E-9-12-94
PH00420-11-1-94