Facer
Electric motors are not explosion proof. Operation
of these components in a hazardous environment
without necessary safety precautions will result in
serious injury and death.
Ensure facer power switch is in the off position.
Connect facer to proper power source.
Don't turn on facer until ready to face.
Remove brushes on the Milwaukee facer motor:
The armature brushes must be removed from the electric motor
when manually operating in a hazardous condition. Unscrew
the brushes from both sides of the motor. (Both brushes must be
removed). A 1-1/8" hex shaft allows for manual operation in
hazardous conditions.
Remove brushes on the Eibenstock facer motor:
The armature brushes must be removed from the electric motor
when manually operating in a hazardous condition.
Remove the rear cover of the motor.
Slide the spring clip away from the brush and pull the brush out
(A).
Loosen the brush ground wire (B) and pull the wire loose.
Repeat these steps on the wire on the opposite side.
Store the brushes in a safe location until needed.
A 1-1/8" hex shaft allows for manual operation in hazardous
conditions.
TX04004-04-07-14
PH04125-4-12-10
Butt Fusion Procedure
3 - 4
PH01847-7-25-00PH04129-4-12-10PH04130-4-12-10PH04130-4-12-10
B
A