Page 145 Speed Level Series - Service & Parts Manual
January 2019Section 9 - Troubleshooting - 3084ES Models
There is a problem with the platform drive/lift select switch – both modes are selected together.
CHECK JOYSTICK SWITCHES! ___________________________ Flash Code: 2/2
There is a problem with the platform joystick switches – both directions are selected together.
RELEASE TRIGGER! ____________________________________ Flash Code: 2/2
The trigger was closed at power-on, or closed for too long with no function selected.
RELEASE GROUND SWITCHES!___________________________ Flash Code: 2/2
Ground function switches were closed at power-on.
RELEASE JOYSTICK SWITCHES!__________________________ Flash Code: 2/2
Platform joystick switches were closed at power-on, or closed for too long without trigger switch
(see SETUPS/INTERLOCKS/TRIGGER wait).
RELEASE OUTRIGGER SWITCHES!________________________ Flash Code: 2/2
Outrigger switches were closed at power-on.
Wiring Messages
The following are “wiring” HELP messages – problems have been detected which are likely due to
vehicle wiring issues:
FAULT: ENERGIZED VALVE - CHECK P5 WIRING! ____________ Flash Code: 3/2
FAULT: VALVE FEEDBACK HIGH - CHECK VALVE WIRING!_____ Flash Code: 3/2
There is a voltage on one or more valve outputs, when all outputs are off.
Check each valve output to trace where the invalid supply is coming from.
FAULT: CAPBANK VOLTAGE TOO HIGH - CHECK LINE CONT! __ Flash Code: 3/3
The voltage on the B+ stud of the controller (connected to an internal voltage stabilization
capacitor bank) is too high when the line contactor is off. B+ stud voltage should be
approximately 32 volts at idle.
Check the line contactor tips are not welded, and check the power wiring for errors.
FAULT: ENERGIZED LINE CONTACTOR - CHECK P5 WIRING! __ Flash Code: 3/4
There is a voltage on the line contactor coil output, when it is off.
Check wiring to the line contactor coil to trace where the invalid supply is coming from.
FAULT: MOTOR OVERLOAD! ______________________________ Flash Code: 3/5
The power protection circuits in the controller have activated to protect from extreme overload.
Check for short-circuit power wiring; check for a seized or shorted motor.

Table of Contents