DET2/3
40
Specifications
Instrument specifications
Display Backlit, colour, WQVGA display 5.25 in
Operating temperature From -10 to 40 °C (14 to 104 °F)
Operating humidity 90% RH max at 40 °C
Storage temperature From -20 to 60 °C (4 to 140 °F)
Temperature coefficient < ±0.1% per °C over operating Temp.
Environmental protection IP54 operational (lid open)
IP65 storage (lid closed)
Altitude: Up to 2000 m above sea-level.
Measurement connection rating CAT IV 300 V (clamp terminals not isolated from measurement terminals)
Measurement output rating ±50 V 1 A, ac or dc.
Power supply Internal Li-ion battery (rechargeable / replaceable)
External 100 to 240 V ac, 50 - 60 Hz (with adaptor)
External 18V dc supply (65 W)
Battery life 10 h. max. (typically)
Battery charge time Fast recharge to 50%, 3 h for 100%.
Ambient temperature
(battery charge)
0 - 40 ºC
Safety Meets IEC 61010
EMC Meets IEC 61326
Dimensions 315 x 285 x 181 mm
(13.8 x 11.2 x 7.1 in)
Weight 4.8 kg (10.6 lb)
PC data download USB 2.0
Data Management Internal 500 record storage
USB Host Send data to pen drive
Resistivity calculation Wenner
Schlumberger
Tests 2P, 3P, ART (Selective), 4P, Stakeless (clamp) modes
Real time clock Yes
RoHS compliant Yes
Instrument calibration check tool
Electrical specification
Resistance 25 Ω ±0.1%
Mechanical specification
Dimensions 60 x 55 x 25 mm (2.5 x 2.25 x 1 in)
Weight 0.1 kg (0.2 lb) approximately
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com