EasyManuals Logo

MEI CASHFLOW 952 Series User Manual

MEI CASHFLOW 952 Series
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
CashFlow
952X / 952Xe / 9510 User Guide
MEI., 2005 Page 11 Rev: G2
Serial Interface Connector (HII or ccTalk) (4)
CF952X/CF952Xe
This 10-pin connector provides a serial interface to an HII interface or ccTalk
®
for the
CF952X and CF952Xe series. The serial mode is selected via the 8 way DIP switch.
Refer to the CF952Xe Series Product Specification for details about the command set
implementation in support of the ccTalk
®
interface.
CF9510
This connector provides access to the STD212 12V, 10-pin dual inline interface. It provides
the following input/output signals:
Supply Voltage Input (12 volts)
A to F Coin Outputs (output signal)
All Inhibit signal (input signal)
Escrow Return Signal (output signal)
Dynamic Route Inhibit Connector (5)
This is a 9-pin connector that provides input from the machine to the validator. Its function is
to modify coin routing. When a specific exit is full, the host machine will signal to the
validator to redirect subsequent coins to an overflow route.
E.g. If a specific exit route becomes full, the machine will send a signal to the validator
instructing it to route any further coins to an alternative exit route.
This feature is not available in the CF9510 as the product does not support a Separator.
Configuration Switches (6)
The 8 way dual in line (DIL) switch provide a way to manually configure the validator. The
following configurations can be achieved.
Setting the alarm on or off
Selecting dedicated serial HI2 operation
Enable or Inhibit coins and tokens
Teaching of tokens
Teaching of primary, secondary and tertiary routes
CF952Xe
The 8 way dual in line switch behaves slightly differently in the CF952Xe. In these models,
SW2 selects serial mode. Once in serial mode, SW1 is used to then select between HII or
ccTalk
. If SW2 is off, SW 1 reverts to Alarm Enable/Disable functionality.
CF9510
In this variant, DIL switches 3 through 6 are identical to the CF952X/CF952Xe series.
However, switches 1,2 and 7, 8 have different functions. Switches 1 and 2 select the active
output mode, switch 7 selects parallel output teach, and switch 8 selects multi-pulse teach
mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MEI CASHFLOW 952 Series and is the answer not in the manual?

MEI CASHFLOW 952 Series Specifications

General IconGeneral
BrandMEI
ModelCASHFLOW 952 Series
CategoryCash Counters & Coin Sorters
LanguageEnglish

Related product manuals